[YamaT, Oshino, Kokeyama, Yoshimura, Tamori, K Tanaka, Akutsu, remote-Shoda / 2019 June 4th-6th]
We are done the real-world cabling for TMSY.
- Circuits were mounted in the TMSY rack. The Schematic is:
https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=10293
For the cable connection, handwritten notes are uploaded at the above document link. See also this and this.
- 12 of 30m Dsub9pin cables were installed by Yoshimura-san and Tamori-san (big thank you to them).
- ADC-DAC assignemnt table was updated:
https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=10292
- TMSY model started at k1ey0.
- Signal chain was checked with the real LVDT and GEOPHONEs. It was GOOD!
- There are minor to-dos (loose screws due to no screw adapter etc) and will be done tomorrow.