Uraguchi, K. Tanaka, Simon, Akutsu in the afternoon
We have successfully installed the TMS-VIS into the EYT chamber. We did it (Fig 3)!
- Uraguchi-san attached six geophones to the TMS-VIS.
- Along with the work, I checked resistors of all the coils and it seemed ok (memo: the following table I measured).
- Then we craned the TMS-VIS with four belt-slings (Fig 1), and broght into the EXT chamber.
- We also fixed some of the fixing bolts (Fig 2).
The installation was originally planed tomorrow; we did faster than our schedule.) We will install the BRT part on the TMS-VIS tomorrow.
Table to show my measurement. The nominal values should be
- LVDT inner coil: 210 ohm, 67 mH
- LVDT outer coil: 180 ohm, 42 mH (see for example here)
- Act coil: 133 ohm, 55 mH (see for example here)
Note that two "LVDT outer coils" are parallelly connected to pin 2-7, so the nominal values of them should be half of the above.
| LVDT, actuator | Resitances between two pins |
| LVDT8, Act18 |
Pin 1-6: 211 ohm Pin 2-7: 90 ohm Pin 3-8: 136.2 ohm |
| LVDT11, Act1 |
1-6: 211 ohm 2-7: 91.7 ohm 3-8: 135 ohm |
| LVDT9, Act16 |
1-6: 210 ohm 2-7: 91.1 phm 3-8: 134 ohm |
| LVDT12, act6 |
1-6: 213ohm 2-7: 89.8 ohm 3-8: 135.8 ohm |
| LVDT6, act13 |
1-6: 211.5 ohm 2-7: 90.6 ohm 3-8: 135.7 ohm |
| LVDT10, act17 |
1-6: 211.4 ohm 2-7: 90.6 ohm 3-8: 135.5 ohm |