Reports 1-1 of 1 Clear search Modify search
AEL (General)
yutaro.enomoto - 18:44 Friday 15 March 2019 (8422) Print this report
Measurement on a harmonic generator (S1909725)

[Tomura, Shimode]

Here I share the measurement results.

input  5.626987250MHz  10dBm       13dBm      Wenzel
x2   11.25MHz         11.81dBm    13.26dBm   12.5dBm
x3   16.88MHz         10.68dBm    13.43dBm   12.7dBm
x5   28.13MHz         11.79dBm    14.15dBm   13.4dBm
x6   33.76MHz         11.93dBm    13.57dBm   13.1dBm
x7   39.39MHz         11.66dBm    13.04dBm   12.6dBm
x8   45.02MHz          9.858dBm   12.78dBm   12.6dBm
x9   50.64MHz         11.40dBm    13.92dBm   13.3dBm
x10   56.27MHz         12.52dBm    14.07dBm   13.3dBm
x16   90.03MHz          7.941dBm   13.44dBm   13.2dBm
x30  168.8MHz          11.94dBm    13.51dBm   13.5dBm

Search Help
×