VIS (PR3)
yoshinori.fujii - 22:46 Wednesday 27 February 2019 (8238) Print this report
some of PR3-IM channels were dead

= PR3 =
-- It was found that some of IM-OSEM signals (v1/V2/V3/H1) were off from the MEDM screen in these days, and then found that the corresponding satellite box and coil driver were turned off.
-- However, when I tuned on the coil driver, soon it turned done automatically, due to an over current. (This HPCD(S1605497) was brought back to Mozumi today.)

-- The status of the satellite box was not checked yet though, those coil driver and the sattelite-box are going to be replaced anyhow.

 

Comments to this report:
yoshinori.fujii - 15:40 Sunday 03 March 2019 (8290) Print this report

Enzo, Yoshinori, 

= PR3 =
-- On Feb. 28th 2019, we found that only replacing the HPCD wroked for this issue. newly installed one is S1807815.
-- The performance will be checked with transfer functions.