Reports 1-1 of 1 Clear search Modify search
IOO (IMMT)
keiko.kokeyama - 19:04 Wednesday 09 January 2019 (7599) Print this report
Comment to Installation of IMMT Type-C shield (7595)

Some supplimentary information:

- IMMT1 got three shilds (of the 4 surfaces), where as IMMT2 has only one sheild on the front. 

- IMMT1 moved some reasonable amount as shown below, because of this big surgery. We did not move the positions back this time - leaving it for later with the main ifo alignment. The magnets or anything else were not touching anywhere. The oplev readings before and after this work were:

(Before)
IMMT1 PIT: -34
IMMT1 YAW: 48

IMMT2 PIT: 204
IMMT2 YAW: 19

(After)
IMMT1 PIT: 201
IMMT1 YAW: -251
(out of the range of the segments)

IMMT2 PIT: 216
IMMT2 YAW: 20
(did not move very much)
 