[Stefan-san, Matteo-san, Kohei Yamamoto-san, Kirii-san, Ohishi, Izumi-san, Kokeyama-san, Enomoto-san]
On 30th May:
In the morning, some paramters in digital system have been changed in order to
*adjust the left (H1, H2) and right (H3, H4) imbalance
and to
*adjust little rotation between optical lever axis and mechanical axis
(perhaps due to roll rotation of the mirror).
Then we measured TF again but it seemed not to be improved as expected(see attached).
Izumi-san and Enomoto-san will adjust the parameters again.
Naoko, Yutaro, Kiwamu,
Following Ohiishi-san's discovery of the coils being not well balanced after the IMC alignment work, we re-adjusted the coil output gains.
We excited each coil at a time at 7 Hz and looked at the optical lever yaw spectrum in order to compare the peak height driven by differrent coils. Initially the coils seemed to be balanced to a 50% level which is consistent with the plots that Ohishi-san posted. We then tuned up the output coil gain so that the peak heights of all the coils match.
The attached shows the current best gains. The imbalance seems to be as small as 5-ish% at 7 Hz.
Also, we left an auto measurement running to evaluate the effect at other frequencies. We will have a close look tomorrow at these measurements.
[EDIT]
The measurements are done and they are stored at:
/users/VIS/180530/MCO/MCO_H1_N_180530_1527677795.xml
/users/VIS/180530/MCO/MCO_H2_N_180530_1527677978.xml
/users/VIS/180530/MCO/MCO_H3_N_180530_1527678162.xml
/users/VIS/180530/MCO/MCO_H4_N_180530_1527678346.xml