Abstract:
I checked the BS sensors for inertial damping.
The cradle effect seems small compared with SRM.
Detail:
I measured the transfer functions of BS when exciting IP L/T/Y with TWR_FLOAT state.
Fgure 1 -3 shows the results.
Left pannels show the transfer functions from each excitation to each blended sensor.
Right pannesls show the relatve gain and phase between LVDT signals and geophone signals (both calibrated into displacement).
Relative gains are less than 1dB at 50 mHz, and relative phases are around 15 degree, which comes from high-pass filter in ACCINF and ACCBLEND filter banks.
So, the cradle effect is small compared to SRM.