takahiro.yamamoto - 21:41 Thursday 19 November 2026 (37890) Print this report
daqd restart of k1nds2
As of yesterday, I had received reports that fast data couldn't be retrieved on k1nds2, but I found some time for reading various logs today and fixed the issue.

Since the mount point was stale, I force-unmounted it and then remounted it. After that, I also restarted the daqd and nds processes. This issue seemed to occur at 4:22 on this Monday.
Nov 16 04:22:07 k1nds2 nds[23225]: [Mon Nov 16 04:22:07 2026] FATAL: archive `/frames/full/' is empty

We have encountered this issue several times over the past month or two (e.g. klog#37613), and since the NIC is showing errors periodically, it’s possible that simply restarting the software isn’t fully resolving the problem. Since the uptime has exceeded 650 days, it might be best to perform a full OS reboot to clear all errors. I plan to do this during the next maintenance window.