Guardian log is as follows.
2026-11-17_02:52:21.237913Z -oStrictHostKeyChecking=no -i /kagra/apps/agilis/id_ed25519_agilis_p_callback x.x.x.x 1 1 ******* IFO_REFL
2026-11-17_02:52:21.652699Z VendorID 4173
2026-11-17_02:52:21.652699Z ProductID 12294
2026-11-17_02:52:21.655325Z Traceback (most recent call last):
2026-11-17_02:52:21.655325Z File "/kagra/apps/agilis/agilis-p_control_with_callback.py", line 387, in
2026-11-17_02:52:21.655325Z node, channel, axis, cur_pos = main(device)
2026-11-17_02:52:21.655325Z File "/kagra/apps/agilis/agilis-p_control_with_callback.py", line 298, in main
2026-11-17_02:52:21.655325Z device.init(iserial,axis)
2026-11-17_02:52:21.655325Z File "/kagra/apps/agilis/agilis-p_control_with_callback.py", line 46, in init
2026-11-17_02:52:21.655325Z raise ValueError('Device is not connected')
2026-11-17_02:52:21.655325Z ValueError: Device is not connected
I also tried to directly access the USB devices on k1hwp, but valid device cannot be found. This means that we need to try rebooting k1hwp once. After the reboot, finding 0 position of HWP is necessary and it requires to stop INITIAL_ALIGNMENT guardian once. But current INITIAL_ALIGNMENT guardian has user code error as follows.
File "/opt/rtcds/userapps/release/lsc/k1/guardian/INITIAL_ALIGNMENT.py", line 4, in
from lsclib import check_io, check_als_x, check_als_y, check_ir_x, check_ir_y, check_ir_x_or_y, check_prmi3f, check_src1f, check_omc, check_srmi1f, check_drmi
ImportError: cannot import name 'check_ir_x_or_y' from 'lsclib' (/opt/rtcds/userapps/release/asc/k1/guardian/lsclib.py)
Because of this error, some guardian command doesn't work and I cannot understand why INITIAL_ALIGNMENT guardian works now with such fundamental code bug.
Unfortunately we have no time to fix it today's daytime due to the fire drill. It will be fix later.