takahiro.yamamoto - 20:13 Sunday 15 November 2026 (37844) Print this report
k1mon9 was dead

As shown in Figure 1, k1mon9 is currently down. According to the last update timestamp of the screenshot on the web interface, it appears to have stopped operating sometime between 10:50 and 10:51.

An attempt was made to reboot the system, but it failed to locate the EFI partition and fell back to PXE boot. Subsequently, an attempt was made to mount the HDD on another server, but even the GPT partition table could not be read. Based on these findings, I concluded that a physical HDD failure was more likely than corruption of the data sectors. Therefore, I decided to abandon HDD recovery and rebuild the boot disk from scratch.

Currently, restoring the configuration for k1mon9 onto the new boot disk is in progress.

Images attached to this report
Comments to this report:
takahiro.yamamoto - 9:42 Monday 16 November 2026 (37849) Print this report
k1mon9 was recovered.
It was constructed as the new Debian13 system.