[Kataoka, Sugioka, Fujimoto, Ushiba, Hirose]
Overview
Since the MICH and SRCL signals at RF51 are likely to have similar demodulation phases, we wrote a Python script to measure the RF signals while sweeping the demodulation phase. The script was developed for DRMI commissioning based on the script of klog36343. (/users/cHirose/script/schnupp_asymmetry_measurement_DRMI.py)
1. RF51 demodulation phase sweep with MICH excitation
We first measured the RF51 signal while exciting MICH.
-
Excitation frequency: 210 Hz
-
OSC CLK gain: 30000
-
S/N ratio: approximately 3(When RF51 demodulation phase: −145 deg)
The measured signal did not show a clear sinusoidal dependence on the demodulation phase, possibly due to the low S/N ratio.
In addition, the excitation amplitude of 50000 was directly applied to the OUTPUT matrix, which may have been too large. The DRMI 1f lock was lost during the measurement.
Therefore, the phase sweep could only be performed from −180 deg to −23 deg (FIg1, FIG2).
2. RF51 demodulation phase sweep with SRCL excitation
Next, we measured the RF51 signal while exciting SRCL.
-
OSC CLK gain: 5000
-
S/N ratio: greater than 10(When RF51 demodulation phase: −180 deg)
The measured signal showed a clear sinusoidal dependence on the demodulation phase.
At the current RF51 demodulation phase setting for 3f (−145 deg), the Q signal was close to its minimum, as expected.(FIg3, FIG4)
3. RF135 demodulation phase sweep with MICH excitation
Finally, we measured the RF135 signal while exciting MICH.(FIg5, FIG6)
-
Excitation frequency: 210 Hz
-
OSC CLK gain: 50000
-
S/N ratio: approximately 10(When RF135 demodulation phase: −180 deg)
The S/N ratio of RF135 was better than that of RF51 under the same MICH excitation conditions.
Currently, the RF135 demodulation phase is set to -119.8 deg, where the RF135 I signal is maximized for PRCL excitation.
It seems difficult to achieve coupling between MICH and PRCL due to the phasing of RF135.