Reports 1-1 of 1 Clear search Modify search
ISC (General)
Hiroki Fujimoto - 3:47 Wednesday 11 November 2026 (37829) Print this report
DRMI 3f sensor decoupling and calibration, and 3f lock trial

[Kataoka, Sugioka, Hirose, Aritomi, Tanaka (online), Komori (online), Ushiba, Fujimoto]

Abstract

We performed decoupling and calibration of the DRMI 3f sensors.
We also attempted to lock the DRMI using the calibrated 3f signals. We successfully performed the 1f-to-3f transition for PRCL and SRCL individually.
However, the transition for MICH was unsuccessful. Further adjustments, such as optimizing the error signal offset and improving the sensor decoupling, are likely necessary.

Details: DRMI 3f sensor decoupling

Since we successfully locked the DRMI with 1f signals yesterday, we used the 1f-locked state to perform decoupling of the 3f sensors.

REFL135-I demodulation phase adjustment

While the DRMI was locked with 1f signals, we excited the PRM at a frequency outside the PRCL control bandwidth and adjusted the REFL135 demodulation phase to minimize the peak in the REFL135-Q spectrum.
The demodulation phase was changed as follows, and the resulting spectra are shown in Fig. 1.

  • K1:LSC-REFL_PDA2_RF135_PHASE_R: 60.2 ⇒ -119.8

REFL51-I/Q demodulation phase adjustment

While the DRMI was locked with 1f signals, we excited the SRM at a frequency outside the SRCL control bandwidth and adjusted the REFL51 demodulation phase to minimize the peak in the REFL51-Q spectrum (i.e., to minimize the SRCL coupling).
The demodulation phase was changed as follows, and the resulting spectra are shown in Fig. 2.

  • K1:LSC-REFL_PDA2_RF51_PHASE_R: -35 ⇒ 145

Reduction of PRCL-to-SRCL coupling

Since REFL51-I contains PRCL coupling, we decoupled the SRCL signal by subtracting REFL135-I from REFL51-I.

First, while the DRMI was locked with 1f signals, we excited the PRM at a frequency outside the control bandwidth and measured the transfer function from REFL135-I to REFL51-I at the excitation frequency.
We then entered the measured value into the input matrix to subtract the PRCL contribution from REFL51-I.
To check the spectrum of the decoupled REFL51-I signal, we routed it through the unused CARM filter bank and monitored its IN1 signal.

Fig. 3 shows the spectra of the raw REFL51-I signal and the decoupled signal (K1:LSC-CARM_IN1). The PRCL coupling was reduced by at least a factor of approximately 7.
The input matrix values were:

  • REFL51-I to CARM: 1.0
  • REFL135-I to CARM: -0.218

SRCL 3f calibration

We calibrated the decoupled SRCL 3f signal into nm, as for the 1f signal, by applying a constant scaling factor.

Specifically, while the DRMI was locked with 1f signals, we measured the transfer function from SRCL1_IN2 to CARM_IN1 to obtain the 3f OLTF.
We then adjusted the scaling factors in the input matrix so that the 3f OLTF matched the 1f OLTF.

Fig. 4 shows the 1f OLTF and the calibrated 3f OLTF for SRCL.
The input matrix values were:

  • REFL51-I to CARM: 4.45
  • REFL135-I to CARM: -0.969

Reduction of SRCL-to-PRCL coupling

Since REFL135-I may also contain SRCL coupling, we decoupled the PRCL signal by subtracting REFL51-I from REFL135-I.

First, while the DRMI was locked with 1f signals, we excited the SRM at a frequency outside the control bandwidth and measured the transfer function from REFL51-I to REFL135-I at the excitation frequency.
We then entered the measured value into the input matrix to subtract the SRCL contribution from REFL135-I.
To check the spectrum of the decoupled REFL135-I signal, we routed it through the unused CARM filter bank and monitored its IN1 signal.

Fig. 5 shows the spectra of the raw REFL135-I signal and the decoupled signal (K1:LSC-CARM_IN1). The SRCL coupling was reduced to the noise floor, corresponding to a reduction of at least approximately one order of magnitude.
The input matrix values were:

  • REFL135-I to CARM: 1.0
  • REFL51-I to CARM: -1.8

*Note: While writing this report, I noticed that the noise floor increased by approximately a factor of 2 after the subtraction. This is because the relatively noisy REFL51-I signal was used for the subtraction, adding noise to the decoupled signal.
However, as described below, we were able to lock PRCL with the 3f signal alone, so this increase in the noise level may not be a serious problem.

PRCL 3f calibration

We calibrated the decoupled PRCL 3f signal into nm, as for the 1f signal, by applying a constant scaling factor.

Specifically, while the DRMI was locked with 1f signals, we measured the transfer function from PRCL1_IN2 to CARM_IN1 to obtain the 3f OLTF.
We then adjusted the scaling factors in the input matrix so that the 3f OLTF matched the 1f OLTF.
Fig. 6 shows the 1f OLTF and the calibrated 3f OLTF for PRCL.

The input matrix values were:

  • REFL135-I to CARM: 0.208
  • REFL51-I to CARM: -0.375

Reduction of PRCL-to-MICH coupling

We decoupled the MICH signal by subtracting REFL135-I from REFL51-Q.

First, while the DRMI was locked with 1f signals, we excited the PRM at a frequency outside the control bandwidth and measured the transfer function from REFL135-I to REFL51-Q at the excitation frequency.
We then entered the measured value into the input matrix to subtract the PRCL contribution from REFL51-Q.
To check the spectrum of the decoupled REFL51-Q signal, we routed it through the unused CARM filter bank and monitored its IN1 signal.

Fig. 7 shows the spectra of the raw REFL51-Q signal and the decoupled signal (K1:LSC-CARM_IN1). However, the PRCL coupling was reduced by only approximately a factor of 2.
The input matrix values were:

  • REFL51-Q to CARM: 1.0
  • REFL135-I to CARM: -0.05

In this measurement, the peak in the REFL51-Q spectrum was only about 6 times higher than the noise floor. A larger excitation may allow more accurate adjustment in the next measurement.

MICH 3f calibration

We calibrated the decoupled MICH 3f signal into nm, as for the 1f signal, by applying a constant scaling factor.

Specifically, while the DRMI was locked with 1f signals, we measured the transfer function from MICH1_IN2 to CARM_IN1 to obtain the 3f OLTF.
We then adjusted the scaling factors in the input matrix so that the 3f OLTF matched the 1f OLTF.

Fig. 8 shows the 1f OLTF and the calibrated 3f OLTF for MICH.
The input matrix values were:

  • REFL51-Q to CARM: 36.7
  • REFL135-I to CARM: -1.84

Details: DRMI 3f lock trial

We attempted to lock the DRMI using the calibrated 3f signals described above, together with the filters, gains, and offsets previously used for the 3f lock. However, we could not acquire the lock at all.
Therefore, we investigated the problem by handing over one DOF at a time from 1f to 3f while keeping the other DOFs locked with 1f signals.

PRCL 3f handover (successful)

We successfully handed over PRCL from 1f to 3f using the same filters and gain settings as for the 1f lock.

SRCL 3f handover (successful)

When we attempted to hand over SRCL from 1f to 3f using the same filters and gain settings, the feedback signal saturated and the lock was lost.
We then reduced the SRCL1 gain from 1.4 to 0.7, which allowed us to complete the handover without any problems.

MICH 3f handover (unsuccessful)

For MICH, the feedback signal initially saturated, as in the case of SRCL.
We therefore reduced the ELP from 500 to 100 and the gain from 9.0 to 2.0.
With these changes, the feedback signal no longer saturated during the transition. However, AS DC gradually drifted, and the lock was eventually lost.
This suggests that we need to optimize the MICH offset for the 3f signal.
In addition, when we measured the PRCL-to-MICH coupling again after some time, we found that the coupling had become worse.
Furthermore, the gain and phase of the 3f OLTF had changed significantly compared with those measured during the calibration described above.
Further investigation is necessary for MICH.

Plans for tomorrow

When we first succeeded in locking the DRMI with 3f signals (⁠klog 37297), the sensor decoupling was not as well optimized as it is now.
Therefore, we would like to spend a little more time trying to achieve the 3f lock using the parameters adjusted yesterday.

  • First, try handing over both PRCL and SRCL to 3f simultaneously.
  • Find an appropriate MICH offset for the 3f signal, since an incorrect offset may cause a large MICH detuning during the handover.
  • If we want to further improve the MICH decoupling, one possible approach is to choose a different REFL51-I/Q demodulation phase, as discussed in ⁠klog 37830.
  • It may also be useful to diagonalize the MICH actuators using the DRMI sensors, as we did previously.

Concerns

Unexplained peak around 14 Hz in the OLTFs

All the OLTFs measured this time, for both 1f and 3f, show an unexplained peak around 14 Hz.
This peak was not present in the OLTFs measured during the recovery work in October (⁠klog 37681).
Although this peak is probably not causing control instability, its origin is still unclear and worth investigating.

Significant change in the MICH optical gain?

In this measurement, the input matrix coefficient required to calibrate REFL51-Q into the MICH error signal in nm was 36.7.
However, during the recovery work in October (⁠klog 37681), this coefficient was 4.8.
Thus, the required coefficient is now almost 7 times larger than before.
This suggests that the MICH optical gain (or possibly the actuator gain?) has decreased to approximately 1/7 of its previous value.
Such a large reduction is not expected from the IMC length adjustment alone, and the cause is currently unknown.