The health check after recovery from the power outage was performed.
- The gains of the TFs in IM L and T were smaller than the references (< 10 dB).
- The gain of the TF in IM V was much smaller than the reference (> 10 dB).
- The TFs in BF V1, V2, and V3 were different from the references.
- The TF in BF V was different from the reference.
- The TFs in F0, F1, and BF GAS were different from the references. The platform may be touching the stoppers vertically.
- The F3 ACT is not working.
- The TFs in IP ACCL and ACCT were different from the references.