Reports 1-1 of 1 Clear search Modify search
VIS (EX)
ryutaro.takahashi - 15:43 Monday 28 September 2026 (37557) Print this report
Health check after power outage

The health check after recovery from the power outage was performed.

  • The gains of the TFs in IM L and T were smaller than the references (< 10 dB).
  • The gain of the TF in IM V was much smaller than the reference (> 10 dB).
  • The TFs in BF V1, V2, and V3 were different from the references.
  • The TF in BF V was different from the reference.
  • The TFs in F0, F1, and BF GAS were different from the references. The platform may be touching the stoppers vertically.
  • The F3 ACT is not working.
  • The TFs in IP ACCL and ACCT were different from the references.
Images attached to this report
Comments to this report:
ryutaro.takahashi - 8:46 Thursday 01 October 2026 (37586) Print this report
Images attached to this comment
ryutaro.takahashi - 14:07 Wednesday 07 October 2026 (37623) Print this report

I offloaded the F3 and BF GAS filters with the FRs after closing the EXC.