DetChar (General)shoichi.oshino - 13:26 Friday 25 September 2026 (37542)
Print this reportSummary pages recoveredSummary pages had not been generated correctly since Sep 23.
- Sep 23: k1sum0 was rebooted (Ikeda-san) - Sep 24: k1ldv0 was started - Sep 25: Plots were still not generated.
The daily summary jobs on k1sum0 failed with "HTTP Error 503: Service Unavailable" when querying the datafind server on k1ldv0. The gwdatafind service (mod_wsgi daemon in httpd) on k1ldv0 had stopped accepting connections since Sep 24 17:06 JST. I restarted httpd on k1ldv0 at 12:16 JST, and the summary pages are being generated again.
The reason why the gwdatafind service stopped is still unknown.
Comments to this report:
shoichi.oshino - 15:02 Monday 28 September 2026 (37556)
Print this reportI regenerated the summary pages of Sep 23 and Sep 24, which had not been produced correctly while the datafind service on k1ldv0 was unavailable. The ALL_GUARDIAN page had not been produced since Apr 13. This was because the following Guardian channels have not been recorded in the frame files since Apr 13. - K1:GRD-LASER_SAFETY - K1:GRD-SYS_NOTIFY I removed these two nodes from the configuration file of the ALL_GUARDIAN page.