Reports 1-1 of 1 Clear search Modify search
DetChar (General)
hirotaka.yuzurihara - 10:05 Wednesday 19 August 2026 (37374) Print this report
DetChar cluster: computing environment, automatic segment production

I resumed preparations for making effective use of the DetChar cluster, including k1detms0 and the computing nodes k1detcl[012]. (past log: klog31462, related slide)
I configured the computing environment to avoid potential issues with Conda and the system clocks.
I found that the wrong disk had been mounted via NFS, so I corrected the configuration to use the proper server.
I started testing the automatic production of segment files using HTCondor. I will continue monitoring the generated files and logs to confirm stable operation.

Details

  • Conda environment
    • I installed the IGWN Conda environment required for the DetChar tools. I used the receipe updated on 2026/08/14. I used the text-based recipe instead of the yaml one to avoid the newer glibc requirement.
    • The conda environment is shared through NFS and is located at /users/DET/conda/miniforge3/envs/igwn-py311/. I confirmed that it works on all four nodes.
  • System clocks on the computing nodes
    • The system clocks on the computing nodes were not synchronized correctly.
    • I enabled and started chronyd so that the system clocks are automatically synchronized.
  • NFS mount configuration
    • The storage storing frame files is mounted at /frame1 via NFS.
    • I updated the NFS configuration to use the current server and confirmed that the frame data can be accessed correctly.
  • Segment generation
    • I manually tested the Segment production script using the new Conda environment.
    • After fixing issues of system clock and NFS maount, the script successfully generated Segment files.
  • Segment generation using HTCondor
    • I set up an HTCondor job to run the Segment production automatically every 15 minutes. I also prepared a script and an HTCondor job to automatically copy the generated Segment files to the product directory at 9:23 every day.
    • Working directory: /users/yuzu/work/20260818_cluster
    • The jobs are currently being tested, and I am monitoring the output, log files, and memory usage to confirm stable operation.
Comments to this report:
hirotaka.yuzurihara - 17:27 Tuesday 06 October 2026 (37617) Print this report

To test the latest version of the DetChar tools, I checked the Segment files automatically generated using HTCondor and compared them with those generated on k1det1.

The files from August 19 and 20 were not consistent. The likely cause was that the HTCondor job ran at 0, 15, 30, and 45 minutes past each hour, before all data for each 15-minute period were available.
I changed the schedule to 3, 18, 33, and 48 minutes past each hour, following the crontab configuration on k1det1.
I will check the results again after a few days.