takafumi.ushiba - 22:12 Wednesday 29 July 2026 (37295) Print this report
Search for good configuration for DRMI characterization

[kTanaka, Ushiba]

Conclusion:

Measurement with time span of 64 s (corresponding to a bandwidth of 0.015625 Hz) with the ADS gains increased by a factor of 3 from their nominal values, except for PRM yaw, appears to provide good results for the sensing matrix measurement.

Detail:

We reviewed the sensing matrix measurement results today (klog37289) and found that the coherence was very low for some degrees of freedom (DoFs).

To investigate the cause, we measured the RF PD spectra while exciting the BS with an amplitude of 30000 counts from ISC_INF.
We found large side lobes located approximately 0.05-0.1 Hz away from the excitation frequency.
Since the sensing matrix measurement had a frequency resolution of 0.125 Hz, these side lobes were not sufficiently separated from the excitation lines.

To mitigate the side lobes, we implemented a second-order boost filter in the MICH filter bank, extending the bandwidth from 1 Hz to 0.1 Hz.
However, the situation did not improve significantly.
Therefore, the side lobes do not appear to originate from residual MICH motion.

We then investigated whether the side lobes were caused by angular motion by examining the OpLev signals and the ASC-MICH_{P,Y} signals.
Since the ASC-MICH_{P,Y} signals exhibit peaks around 0.09 Hz, it is likely that the side lobes originate from angular motion.
Furthermore, the coherence between the ASC signals and the OpLev signals is high for SRM, PRM, and IMMT2, all of which are controlled by ADS.
Therefore, we suspected that the ADS control was producing the peak around 0.09 Hz, which in turn generated side lobes in the LSC signals when the BS was excited at 150.125 Hz.

To address this issue, we increased the ADS gains for IMMT2 pitch/yaw, PRM pitch, and SRM pitch/yaw by a factor of 3 in order to increase the ADS UGFs.
Since the PRM yaw loop became oscillatory when its gain was increased by a factor of 3, the PRM yaw ADS gain was left unchanged.

Figure 1 shows the RF PD spectra measured while DRMI was locked and the BS was excited at 150.125 Hz.
The coherence between the MICH and RF PD signals is high, indicating that the measurement quality is improved compared to the previous measurement.
When comparing the new results with the previous measurement, several values changed by significant factors, suggesting that the previous measurement may not be accurate sufficiently.
Therefore, it would be preferable to repeat the sensing matrix measurement.