Reports 1-1 of 1 Clear search Modify search
MIF (General)
shun.saito - 19:33 Monday 01 June 2026 (36995) Print this report
Continuation of PLL attempt

[Ushiba, Tanaka, Fujimoto, Saito]

Following klog:36974, we attempted to achieve lock by adding an integrator to the low-pass filter, but locking was not successful. We also tried changing the feedback sign, changing the frequency relationship between the main laser and the sub-laser, and using the low-pass filter of SR560 instead of Moku:Lab. However, none of these approaches resulted in lock acquisition. In addition, the measured beat signal amplitude was approximately 0.2 mVpp, whereas the value predicted from the laser powers was approximately 0.1575 V, representing a large discrepancy. Therefore, in the next experiment, we plan to investigate the alignment, mode matching, and polarization conditions to determine whether the beat signal amplitude can be increased.
 

  • First, a 10 kHz low-pass filter was applied, and the gain was gradually increased. Oscillation occurred once the gain exceeded a certain level. We then inserted an integrator with a corner frequency of 1 Hz while keeping the gain just below the oscillation threshold and tested whether lock could be achieved. However, no behavior indicating that the beat frequency was being pulled toward the LO frequency was observed. In addition, when the integrator was enabled, the beat frequency was observed to move further away from the LO frequency. We also changed the feedback sign and tested both cases in which the sub-laser frequency was higher than and lower than the main laser frequency, but lock could not be achieved in any configuration. Furthermore, we attempted to use the low-pass filter of an SR560 instead of Moku:Lab and varied the gain, but lock acquisition was still unsuccessful.
     
  • In addition, when the gain was increased with the 10 kHz low-pass filter in place, the frequency of the error signal at the onset of oscillation was approximately 900 kHz. When the beat signal was observed on the oscilloscope, its amplitude exhibited temporal fluctuations, and the measured frequency was also approximately 900 kHz. This amplitude-modulated signal disappeared when the sub-laser beam was blocked, but remained unchanged when the main laser beam was blocked. The same 900 kHz signal was also observed on the spectrum analyzer. Its level was approximately -43 dB with the noise eater turned off and decreased to approximately -80 dB when the noise eater was turned on. However, changing the state of the noise eater did not enable lock acquisition.

  • The beat signal amplitude, converted from the spectrum analyzer reading in dBm, was approximately 0.2 mVpp. At present, the sub-laser power incident on the RFPD is approximately 1.78 mW, while the main laser power is estimated to be approximately 17 μW. Since the responsivity of the RFPD (1611FS-AC) is approximately 525 V/W, the expected beat signal amplitude is (525V/W)×2√(1.78×10^−3×17×10^−6) which is approximately 0.1575 V. This predicted value is about 788 times larger than the measured amplitude. Therefore, in the next experiment, we plan to investigate the alignment, mode matching, and polarization conditions to determine whether the beat signal amplitude can be increased.

Search Help
×

Warning

×