satoru.takano - 1:15 Wednesday 13 May 2026 (36879) Print this report
SRCL control imnplementation

[Dan, Fujimoto, Tanaka, Takano]

Summary

After adjusting SRM yaw, we successfully implemented the SRCL control with POP f1 signal. Currently the UGF is ~ 18 Hz. Also, SRM ADS worked with AS DC power.

Detail

After the PRM alignment (and the QPD centring work, which was found to be a failure later, though), we tried to close the SRCL control loop. Looking at several RF signals, we decided to use POP f1 I signal, which seemed to have a decent SNR. We copied all the filter banks from PRCL1 and PRCL2 and implemented them into SRCL1 and SRCL2. After tweaking the gain in SRCL2, SRY was stably locked with the setting below:

  • SRCL1: FM9 (pole: 0 Hz, zero: 8 Hz)
  • SRCL2: FM6 (an elliptic low pass with a cutoff at 300 Hz)
  • Gain: -800

With these filter bank settings, the open loop gain was measured as shown in Fig. 1. The UGF was ~ 18 Hz, and the phase margin was 43°.

Following the success of the SRCL control, we implemented a dithering control loop to improve SRM alignment. The dithered frequencies were 4.3 Hz for SRM pitch and 6.3 Hz for SRM yaw, and we demodulated the AS_PDA1_DC signal. The demodulation phase was set as shown in Fig. 2; I set it to 8° for pitch and 13° for yaw. The loops were closed with the gain of -1000 for both pitch and yaw control.

Even though the alignment was improved by SRM ADS, the intracavity buildup was only 1.5, which should be ~ 7, considering the BS and SRM transmission. It was also found that the REFL power increased when SRY was locked, which should be decreased. It might be that we locked SRY to higher-order modes, but judging from the camera images at AS and POP Spol, the fundamental mode appeared to be on resonance. Yesterday, we confirmed that the buildup factor for PRY was ~7, close to the expected value, so the birefringence loss does not seem to limit amplification. We need more information to investigate the reason.

 