Weather station PC at Atotsu has CMOS error

When I tried to migrate a copy process of Weather Station Web pages on k1script, I found k1script couldn't access Weather Station@Atotsu.
It was since Feb. 9th according to the last update on the Web page.
Weather Station@Atotsu cannot be launched due to CMOS error now.
A replacement of a CMOS battery (or PC itself in the worst case) seems to be required to recover it.

-----
A copy process of Weather Station Web pages was migrated from the old k1script1 to the new k1script0. This process for Weather Station at Mozumi works fine. On the other hand, it for at Atotsu couldn't access Weather Station PC. Because the old process on k1script1 was also failed, I concluded that it was a problem on the Weather Station PC not on the k1script.

Any remote connections wasn't available, so I checked a situation by plugging a display to the Weather Station PC at Atotsu and found that gathering hardware information before booting OS up failed due to the CMOS trouble as shown in Fig.1. This message is also shown when a CMOS battery (often use CR2032 on common server) becomes empty. Of course, there is some possibility about a malfunction of a motherboard. Anyway what we can try at first is opening PC chassis, and then replacing the CMOS battery if there is no obvious malfunction on the mother board.