Reports 1-1 of 1 Clear search Modify search
VIS (General)
ryutaro.takahashi - 17:27 Friday 06 March 2026 (36516) Print this report
Offload of GAS filters and IPs

I offloaded the following GAS filters and IPs with the FRs for the recovery from the power outage.

  • SRM: F0 GAS, H1 IP
  • SR2: F0 GAS
  • SR3: F0 GAS
  • BS: F0 and F1 GAS
  • ITMX: F0, F1, F2, and BF GAS
  • ITMY: F0, F1, F2, F3, and BF GAS
  • ETMX: F0, F3, and BF GAS
  • ETMY: F0, F1, F2, F3, and BF GAS, H1 and H2 IP
  • PR3: SF and BF GAS (FR for SF GAS reached SW limit)
Comments to this report:
ryutaro.takahashi - 14:16 Saturday 07 March 2026 (36523) Print this report

I offloaded the following GAS filters and IP with the FRs.

  • ITMX: F0 GAS
  • ITMY: F0 GAS
  • ETMY: F0 GAS, H2 IP
ryutaro.takahashi - 9:00 Sunday 08 March 2026 (36524) Print this report

I offloaded the F0 and F1 GAS filters in IX with the FRs.

ryutaro.takahashi - 20:52 Monday 09 March 2026 (36534) Print this report

I offloaded the following GAS filters with the FRs.

  • ITMX: F0 GAS
  • ITMY: F0 and BF GAS
  • ETMX: F0 and BF GAS
  • ETMY: F0, F1, F3, and BF GAS
Search Help
×

Warning

×