Reports 1-1 of 1 Clear search Modify search
PEM (Center)
takaaki.yokozawa - 8:52 Friday 30 January 2026 (36250) Print this report
PEM injection 260130
I performed the PEM injection test, especially the acoustic injection to PSL room
EXC : K1:PEM-EXCITATION_MCF0_RACK_13_EXC

2026/01/30 05:06:00 - 05:26:00
300 - 400 Hz, 1 Hz resolution, 10 s in each frequency, 100 cnt

2026/01/30 05:27:00 - 05:47:00
300 - 400 Hz, 1 Hz resolution, 10 s in each frequency, 100 cnt

Locked loss

2026/01/30 06:33:00 - 07:13:00
100 - 300 Hz, 1 Hz resolution, 10 s in each frequency, 100 cnt

2026/01/30 07:15:00 - 07:50:00
50 - 900 Hz, 5 Hz resolution, 10 s in each frequency, 100 cnt

2026/01/30 07:50:00 - 08:05:00
Silent run

2026/01/30 08:05:00 - 08:15:00
White injection, all frequency, 1000 cnt (Fig.1.)

2026/01/30 08:15:00 - 08:25:00
White injection, 280 - 420 Hz, 1000 cnt

2026/01/30 08:25:00 - 08:30:00
White injection, 280 - 420 Hz, 2000 cnt

2026/01/30 08:25:00 - 08:30:00
White injection, 280 - 420 Hz, 2000 cnt

2026/01/30 08:30:00 - 08:35:00
White injection, 180 - 220 Hz, 2000 cnt

2026/01/30 08:35:00 - 08:40:00
White injection, 80 - 220 Hz, 2000 cnt

2026/01/30 08:40:00 - 08:45:00
White injection, 380 - 520 Hz, 2000 cnt

2026/01/30 08:45:00 - 08:50:00
White injection, 480 - 620 Hz, 2000 cnt

2026/01/30 08:50:00 - 08:55:00
White injection, 580 - 720 Hz, 2000 cnt

2026/01/30 08:55:00 - 09:00:00
White injection, 680 - 820 Hz, 2000 cnt
Images attached to this report
Comments to this report:
tatsuki.washimi - 22:25 Sunday 01 February 2026 (36255) Print this report

I analyzed the (BL-)white noise acoustic injection in the PSL room.

I assumed the coupling is linear and applied the Coupling Function model.

The current sensitivity is limited by the PSL room sound at 200-600 Hz.

Images attached to this comment
tatsuki.washimi - 22:27 Sunday 01 February 2026 (36256) Print this report

supplemental plots

Images attached to this comment
tatsuki.washimi - 9:41 Monday 02 February 2026 (36257) Print this report
Images attached to this comment
tatsuki.washimi - 12:52 Monday 16 February 2026 (36366) Print this report

I checked responses of QPDs related to the PSL, IMC, and IMMT, for the acoustic injection tests on Jan. 30th.

  • Well excited channels
    • K1:PSL-IP_QPD1_DC_PIT_OUT_DQ
    • K1:PSL-IP_QPD1_DC_YAW_OUT_DQ
    • K1:PSL-IP_QPD2_DC_PIT_OUT_DQ
    • K1:PSL-IP_QPD2_DC_YAW_OUT_DQ
    • K1:IMC-REFL_QPDA1_DC_PIT_OUT_DQ
    • K1:IMC-REFL_QPDA1_DC_YAW_OUT_DQ
    • K1:IMC-REFL_QPDA1_RF14_I_PIT_OUT_DQ
    • K1:IMC-REFL_QPDA1_RF14_I_YAW_OUT_DQ
    • K1:IMC-REFL_QPDA1_RF14_Q_PIT_OUT_DQ
    • K1:IMC-REFL_QPDA1_RF14_Q_YAW_OUT_DQ
    • K1:IMC-REFL_QPDA2_DC_PIT_OUT_DQ
    • K1:IMC-REFL_QPDA2_DC_YAW_OUT_DQ
    • K1:IMC-REFL_QPDA2_RF14_I_PIT_OUT_DQ
    • K1:IMC-REFL_QPDA2_RF14_I_YAW_OUT_DQ
    • K1:IMC-REFL_QPDA2_RF14_Q_PIT_OUT_DQ
    • K1:IMC-REFL_QPDA2_RF14_Q_YAW_OUT_DQ
  • Little excited channels
    • K1:IMC-IMMT1_TRANS_QPDA1_DC_PIT_OUT_DQ'
    • K1:IMC-IMMT1_TRANS_QPDA1_DC_YAW_OUT_DQ
    • K1:IMC-IMMT1_TRANS_QPDA2_DC_PIT_OUT_DQ
    • K1:IMC-IMMT1_TRANS_QPDA2_DC_YAW_OUT_DQ
  • Not excited channels
    • K1:IMC-MCE_TRANS_QPDA1_DC_PIT_OUT_DQ
    • K1:IMC-MCE_TRANS_QPDA1_DC_YAW_OUT_DQ
    • K1:IMC-MCE_TRANS_QPDA2_DC_PIT_OUT_DQ
    • K1:IMC-MCE_TRANS_QPDA2_DC_YAW_OUT_DQ
Images attached to this comment