MIF (General)takaaki.yokozawa - 9:20 Friday 16 January 2026 (36151)
Print this reportPRFPMI RF PRMI 1F locked The lock of the PRFPMI RF with RPMI 1F lock succeeded, next tuning of the ASC with PRFPMI Fig.1. - Fig.3. showed the OLTF of the DARM, MICH and PRCL.
Images attached to this report
Comments to this report:
takaaki.yokozawa - 13:41 Tuesday 20 January 2026 (36179)
Print this reportDARM : consistent MICH : increased the 1.792 dB from reference, so I will add the -1.792 to FM2 in MICH2 filter bank PRCL : reference was too old (Komori-san's update for PRCL control), I modified the reference (2025/11/04) (Fig.1.) increased the 2.095 dB from reference, so I will add the -2.095 to FM3 in PRCL1 filter bank
Next, investigation of the CARM gain with LSC_LOCK guardian set PRFPMI_LOCKD_WITH_3F request VERTEX guardian to PRMI_LOCKED (before the rotation, we want to measure the CARM OLTF)
Then, set the threshold for the LSC-REFL_PDA1_DC_OUTPUT (L2043 LSC_LOCK guardian)
Images attached to this comment
takaaki.yokozawa - 13:51 Tuesday 20 January 2026 (36180)
Print this reportI also measured the CARM OLTF.
In case of the REFL_HWP=155 with PRFPMI_1F RF locked, the UGF was about 8 kHz as shown in Fig.1. Then I rotated the REFL_HWP (=135), the UGF changed to about 30 kHz, but even we rotated the HPW more, the UGF didn't change.
So I changed the IN1 gain for CARM CMS from -24 dB to -21 dB, the UGF became about 40 kHz (Fig.2.)
After discussion with Ushiba-san, we decided to change it in the Increase CARM_GAIN L2063 self.gain = -21 #-21 CMS_CARM.gain('IN1',self.gain)