DGS (General)takahiro.yamamoto - 16:10 Thursday 15 January 2026 (36145)
Print this reportComment to New equipments for ITM front-end (36129)[Ikeda, YamaT]
We launched up a new V4 computer as K1IZ1. Now both V4 front-end and a new IO chassis are in the server room to check the stability with short cable connection. And also, K1IZ1 runs only with PXE/NFS connection to k1boot and without DAQ/RFM connection to another CDS nodes to separate from existing control system. After checking the stability by short cable connection during next few weeks, a new IO chassis will be moved to IXV or IYV area to check a stability with long (~100-150m) cable connection. After starting SRM work in March, K1IZ1 will be connected to DAQ/RFM and finally it will be replaced as current ITMX or ITMY until the end of March.
For launching K1IZ1, node information was added to dhcp@k1boot and dns@k1gate.
----- Rack layout - An unused old type of IO chassis (S1605837) were moved from U8-11 of C2 rack to U6-9 of C4 rack. - K1IZ1 front-end and a new type of IO chassis (S2416127) were installed at U29-30 and U8-11 of C2 rack, respectively. - Spare V4 computer at U1-2 was brought back to SK building for future tests.
Card configuration (same as ITMX and ITMY - 1 IRIG-B card in front-end - 1 RFM card in front-end - 1 4-port Adnaco card in front-end - 3 ADC boards (S2213882, S2213881, S2113340) in IO chassis - 3 DAC boards (S2012040, S2517026, S1605727) in IO chassis - 1 BIO1616 board in IO chassis - 5 BIO6464 boards in IO chassis - 1 BO32 board in IO chassis