I have uploaded the OLTF of PMC measured last week (Fig. 1). You can use the numerical data if needed.
Measured UGF was ~1.5kHz at -10dB since 10dB gain exists in the circuit between measured points.
I have uploaded the OLTF of PMC measured last week (Fig. 1). You can use the numerical data if needed.
Measured UGF was ~1.5kHz at -10dB since 10dB gain exists in the circuit between measured points.