MIF (General)takaaki.yokozawa - 12:03 Friday 07 November 2025 (35521)
Print this reportLock loss investigation 251106 night - 251107 morning[Yuzu, Yokozawa]
We performed the investigation of the lock loss last night.
Compared from yesterday, we cannot see the lock loss due to the ETMX kick.
Lock loss lists # 1562 2025-11-06 10:54:57.562500 UTC ( 17468s) # 1563 2025-11-06 11:48:24.687500 UTC ( 438s) # 1564 2025-11-06 13:23:24.937500 UTC ( 3650s) # 1565 2025-11-06 20:30:29.812500 UTC ( 23721s) # 1566 2025-11-06 21:20:26.937500 UTC ( 1408s)
ETMY MN oplev glitch #1565, #1566
Nearby Earthquake #1564
PRCL control signal became strange. #1562, #1563 We checked more carefully about those locked losss Fig.1. showed the PRCL LSC related channels, obviously, the signal saturation detected in POP RF45 I,Q (RFPD signal for the PRCL 1f lock) We don't know the origin of this glitch, it happened several times (Other time in Fig.2. and Fig.3.)