Ryoya Ishikawa - 15:04 Wednesday 29 October 2025 (35434) Print this report
Reported the scattered light noise

[Yuzurihara, Ishikawa]
As a continuous analysis of klog35268, we found scattered light noise appearing the strain channel(K1:CAL-CS_PROC_DARM_STRAIN_DBL_DQ) on 2025/7/15 and 16.
The scattered light noise appeared in the frequency range around 70 Hz.
Figure 1~3 show the Q-spectrogram of the strain signal. This segment bar indicates the approximate time of the inspiral range drop found in this analysis.

Images attached to this report
Comments to this report:
Shih-hong Hsu - 17:11 Wednesday 12 November 2025 (35558) Print this report

[Shih-Hong Hsu, Chia-Jui Chou, Hirotaka Yuzurihara, Yi Yang]

 

In klog-35434, Ishikawa-san reported scattered light noise in the STRAIN channel (K1:CAL-CS_PROC_DARM_STRAIN_DBL_DQ) data for 2025-07-15 and 07-16. We investigated the scattered light noise with the method mentioned in JGW-G2416344

The characteristic feature of scattered light noise found on 2025-07-15 includes:

  1. Characteristic frequency band: 70 [Hz]

  2. Time difference between arch-shapes: 1.5 [s]

  3. Be found in the STRAIN data but not in MICH (K1:LSC-MICH_OUT_DQ) or PRCL (K1:LSC-PRCL_OUT_DQ) data.

While the feature of scattered light noise in April includes:

  1. Characteristic frequency band: 30 [Hz]

  2. Time difference between arch-shapes: 1.15 [s]

  3. Can be found in STRAIN, MICH, and PRCL data.

This result suggests that the source of the scattered light noise in these two periods may be different. A detailed analysis result is also uploaded to the JGW server as JGW-G2516978-v1.

 

Figure 1: The spectrogram of the scattered light noise in April (left, 4-13) and on 7-15. 

The noise is plotted in the spectrogram from the constant Q-transform. The Q value in these is different for a better resolution. f_sc is the frequency of the scattering motion of the source, which is calculated from the inverse of doubling the time difference between the arch shapes. 

Figure 2: The spectrogram of STRAIN (left), MICH (middle), and PRCL (right) channels in April (upper, 4-13) and on 7-15 (lower).

The scattered light noise in April appears simultaneously in the STRAIN, MICH, and PRCL channels' data, while the scattered light noise from 7-15 only appears in the STRAIN channel.

Images attached to this comment
Search Help
×