Reports 1-1 of 1 Clear search Modify search
VIS (EY)
takafumi.ushiba - 20:02 Tuesday 28 October 2025 (35429) Print this report
ETMY NB damp tuning

To solve the oscillation issue for ETMY, I tuned ETMY NBDAMP_L5.
Figure 1 shows the OLTF of NBDAMP_L5.
Due to the double peak around 1.7Hz, gain peaking at 1.73Hz is higher than before, so further tuning might be necessary.

Images attached to this report
Comments to this report:
takafumi.ushiba - 9:28 Wednesday 29 October 2025 (35431) Print this report

Figure 1 shows the filter bank I modified.
Old filter was moved from FM3 to FM2 and new filter was implemented at FM3, so no SDF change happens.

Images attached to this comment