With Misato Onishi
We performed monthly Pcal-X calibration on 2025/8/27.
After the calibration, we updated EPICS parameters related to the Pcal-X system.
No issues were found.
| EPICS Key | Before | After |
|---|---|---|
| K1:CAL-PCAL_EX_1_PD_BG_TX_V_SET | 0.00632 | 0.00696 |
| K1:CAL-PCAL_EX_2_PD_BG_TX_V_SET | 0.00528 | 0.00598 |
| K1:CAL-PCAL_EX_1_PD_BG_RX_V_SET | -0.00380 | -0.00378 |
| K1:CAL-PCAL_EX_1_OE_T_SET | 0.98478 | 0.98513 |
| K1:CAL-PCAL_EX_1_OE_R_SET | 0.98478 | 0.98513 |
| K1:CAL-PCAL_EX_2_OE_T_SET | 0.97744 | 0.97746 |
| K1:CAL-PCAL_EX_2_OE_R_SET | 0.97744 | 0.97746 |
| K1:CAL-PCAL_EX_1_RX_V_R_SET | 0.50223 | 0.50213 |
| K1:CAL-PCAL_EX_2_RX_V_R_SET | 0.49777 | 0.49787 |
| K1:CAL-PCAL_EX_WSK_PER_TX1_SET | 0.52695 | 0.52709 |
| K1:CAL-PCAL_EX_WSK_PER_TX2_SET | 0.38723 | 0.38723 |
| K1:CAL-PCAL_EX_WSK_PER_RX_SET | 1.48964 | 1.48948 |
| K1:CAL-PCAL_EX_2_INJ_V_GAIN | 0.95074 | 0.95201 |