MIF (General)takaaki.yokozawa - 12:49 Tuesday 05 August 2025 (34748)
Print this reportComment to IFO recovery from earthquake in Kamchatka Peninsula: Day 2 (34739)Changing guardian for the temporal solution, we need to discuss about it.
lsclib.py L169 for ax in ['DHARD', 'CHARD','DSOFT', 'CSOFT', 'MICH', 'INP1' ,'INP2', 'PRC2']: -> for ax in ['DHARD', 'CHARD','DSOFT', 'CSOFT', 'MICH', 'INP1' ,'INP2','PRC1', 'PRC2']:
L199 for ax in [ 'MICH', 'INP1', 'INP2', 'PRC2']: -> for ax in [ 'MICH', 'INP1', 'INP2', 'PRC1','PRC2']:
L229 for ax in ['MICH', 'PRC2']: -> for ax in ['MICH', 'PRC1', 'PRC2']:
ASC_LOCK.py L403 : for DOF in ['MICH','PRC2','INP1','INP2']: -> for DOF in ['MICH','PRC1','PRC2','INP1','INP2']:
L1574 ezca['ASC-PRC1_%s_TRAMP'%(dof)] = 0
L1660 ezca['ASC-PRC1_%s_GAIN'%(dof)] = 0
L1668 ezca['ASC-PRC1_%s_TRAMP'%(dof)] = 5
L1897 for DOF in ['MICH','PRC2','INP2']: -> for DOF in ['MICH','PRC1','PRC2','INP2']: