Reports 1-1 of 1 Clear search Modify search
DGS (General)
takahiro.yamamoto - 15:04 Tuesday 29 July 2025 (34696) Print this report
Preparation of nightly measurements
I prepared a new script to do nightly measurements as /users/Commissioning/scripts/NightlyMeasurements/scripts/nightly_measurement.py.
Though test of each function was done, end-to-end test couldn't be done because IFO didn't come back until the end of today's commissioning time.
Remaining test items are
- does IFO transit from Observing-mode to Working-mode properly by this script at the beginning of measurements?
- is ongoing measurement surely stopped when lockloss occurs?
- is the script surely stopped when OBS_INTENT is accidentally raised?
- does IFO come back from Working-mode to Observing-mode by this script after the end of measurements?

Workflow of this script is available on JGW-D2516766