shinji.miyoki - 23:49 Sunday 20 July 2025 (34610) Print this report
IFO could not be recovered after the long lock loss caused by several big earthquakes

IFO could not be recovered after the long lock loss caused by several big earthquakes.

After GR lock, PRMI_3F_LOCkED state could not be realized for a long time. No resonance in both arms were found.

Sometimes, "waiting for BS calm down" was shown.

Images attached to this report
Comments to this report:
shinji.miyoki - 5:44 Monday 21 July 2025 (34611) Print this report

Fig. 1 shows the ETMX/ITMX oplev changes before and after the isolated state is triggered by large earthquakes.

ITMX HOR seemed to be different by 2 urad. ETMX HOR seemed to drift significantly before the lock loss.

Fig. 2 shows the ETMY/ITMY oplev changes before and after the isolated state is triggered by large earthquakes.

Almost the same values were kept before and after.

Fig3 shows the BS, PR2/3, and SR2/3 OPLEV values.

Almost all values were recovered as before the lock loss.

I requested DOWN in the LSC_LOCK guardian around 5:00 JST maybe because the PRMI alignment seemed to be destroyed.