Comment to Weekly calibration on 7/11 (34533)

I updated line tracking parameters (JGW-L2314962).

All detected changes are coming from the planned commissioning activities.
- Changes in foton Fig.1 are related to klog#34533 (k1calcs).
- No changes in guardian (Fig.2).
- Changes in SDF tables shown in Fig.3-4 are related to this klog#34515, klog#34532, klog#34534 (k1calcs), klog#34513, klog#34531 (k1calex, k1caley).
- No changes in the model (Fig.5).

Changes in SDF table by klog#34520 (k1sdfmanage) were not detected because it was accepted/reverted on down.snap instead of observation.snap. So SDF diffs are still remaining on k1sdfmanage. I checked that remaining differences are same as processed on down.snap in klog#34520 or not. Then I found some inconsistency between the processed differences and current values. So I cannot decide how should we process this remaining changes. So IFO guardian is still in LOCKED.