Ikeda, Hirose
During the observation shift, there is a “Cryocooler Temperature Change” item in the dairycheck items.
The task is to record the temperature of the cryocooler at AM10:00 and PM4:00 during the Saturday and Sunday shifts, and to compare it at AM10:00 with the previous day's PM4:00, and at PM4:00 with the same day's AM10:00.
However, in the case of the AM10:00 check on Saturday, we need to compare the temperature of the cryocooler unit with the temperature at PM4:00 on Friday.
We created ndscope templates to see the temperature changes of cryocoolers and set it to medmscreen.(FIG1)
OPERATOR_O4c.adl->the side part of "CRY"->"ARM/BRT/BS HEAD(FIG2)", "ARM/BRT/BS BAR(FIG3)", "REF1,2,3,4 50K HEAD(FIG4)", "REF1,2,3,4 50K BAR(FIG5)", "REF1,2,3,4 4K HEAD(FIG6)", "REF1,2,3,4 4K BAR(FIG7)"