takafumi.ushiba - 22:30 Tuesday 24 June 2025 (34356) Print this report
Comment to WFS offset tweaking (34349)

Abstract:

Since there is large peak around 140Hz, I reverted alignment to the one during last week to investigate the reason of the peak around 140Hz.
However, even though all settings were reverted, there was a peak around 140Hz.
Since the peak height sometimes became small when tweaking WFS offsets, it would be reduced by alignment, so I continued alignment tweaking today.

Detail:

According to the spectrum during the night run yesterday, there is a peak around 140Hz while it was not there last week (fig1: blue cursor).
Alignment setting during last night was different from the one last week, especially ITMY beam spot is closer to the center, so I checked if the peak appeared due to ITMY beam spot or not.
Since the peak looks broad and the sensitivity around 140Hz affects BNS range, further sensitivity improvement is expected if we remove that peak.
So, I reverted IFO alignment setting to the one last week and checked the sensitivity.

Since GRX seems to move a lot, especially in yaw, I first checked the beam spot on PR2 by using both POP FORWAD QPDs and PR2 BPC signals to confirm IR alignment doesn't change.
Figure 2 shows the QPD signals after reverting IFO setting, which seems to be fine (Y cursor shows the values last week).
In addition, BPC signals cross to zero (apply 5 cnts from CLK GAIN), which means beam spot on PR2 should be almost centered.
So, there seems no change in IR beam path.
After confirming that, I aligned GRX by using PICO motors on POP table.

Then, I checked the sensitivity with the reverted alignment and found that there is a peak even with this configuration (fig3).
Therefore, it doesn't seem to appear due to ITMY beam spot yesterday.
So, I continued the alignment tweaking with ITMY P2L drive align matrix of -1.6, which is smaller the the original value (-2.5), to reduce the pitch thermal noise.

Changes during the work:

During the BPC signal checking, I modified the filter of K1:BPC-YAW_PR2_DEMOD_{I,Q} filters (fig4, fig5: added LP0.1).
In addition, I increased gain of ETMX tidal compensation (FM1, FM2, and FM3 of IP_ISC2LVDT_L filter bank) to supress the MN actuator feedback signals and reduce the breathing around 80 Hz.
I also changed all WFS offsets to zeros because offsets sometimes disturbs the ASC engagement during the lock acquisition.
After confirming the good offset values, it would be necessary to modify the guardian so that adding offset after ASC is fully engaged.