shinji.miyoki - 14:00 Monday 23 June 2025 (34346) Print this report
Comment to Timing synchronization was lost on ITMX and ITMY (34320)

[Miyakawa, Oshino, Miyoki, Hayakawa, Ohmae, Yamaguchi, Ushiba(ControlRoom)]

I confirmed that the power supply(PS) situation is the same as the last case, in other words, the current trip is at ~ 2.5A, and ~ 2V output (Fig.1).

I also noticed that the inside of the 19-inch rack that houses fanout, IRIG-B, HDDs, and PS for fanout/IRIG-B, and several PS for the DGS systems was so hot. The front panel and rear panel that had mesh holes were closed. I checked the air flow inside the 19-inch rack between the opening and closing of these panels. When they were open, the air flowed from the back of the  PS for the DGS systems and HDD units to the rear side. On the other hand, I felt a tiny air flow through the rear panel if the rear panel was closed. When I opened the rear panel again, I felt hotter air inside the 19-inch rack. I checked the temperature outside of the 19-inch rack, then it was ~29C. The PS for fanout/IRIG-B seemed to have no fan inside. In addition, one side wall of the PS for fanout/IRIG-B was almost covered with the side panel of the 19-inch rack shelf. This situation also contributes to enhancing the temperature inside the PS.

I urgently turned off the PS. However, Oshino-kun and Miyakawa-kun seemed to have a plan to measure the resistance between the 12V output and the ground to check whether the shorting had happened or not. Sorry for my quick action.

We discussed what was the source of this accident. However, we could not clearly identify it under this situation. Miwakawa-kun noticed that this PS had a trip function. If a trip happens, the red light should be illuminated in the front panel. However, it was not illuminated. So, some kind of trip could not happen. While the current limit happened in this PS. This is a kind of abnormal situation. 

Then we discussed what the possible trials were to identify the trouble source.

  1. Anyway, we try to turn on the SP again without any change, whether the shorting situation still continues or not.

Then we confirmed that the PS could work! and fanout/IRIG-B were rebooted without any troubles. In addition, we decided to make a space on the closed side of the PS as instructed in the manual (Fig.2). Then what is the next?

  1. Assuming the hotter environment resulted in this abnormal situation, we will keep the present instruments and connections after preparing some methods to cool them.
  2. Prepare one new (not new actually, but used in other places) PS, instead of the present PS, because the suspected instrument should be replaced in general.
  3. Prepare two PSs for fanout and IRIG-B individually. Then check their situation.

We selected 1). 

To cool inside the 19-inch rack, anyway, we removed the front and rear panels. In addition, I asked Hayakawa-kun's team to relocate the water cooling type cooler to the front of this 19-inch rack and put two circulators in front of this cooler to send the cool air to the PS and IRIG-B/fanout units (Fig.3,4).

The temperature at each point is shown in Fig.5(output of the cooler),6(near PS for fanout/IRIG-B),7(fanout/IRIG-B).

We will monitor what will happen or not.