takahiro.yamamoto - 3:41 Tuesday 03 June 2025 (34035) Print this report
Comment to Finalization of observation.snap for each model (33903)

I accepted following SDF differences.
 

k1calcs

K1:CAL-MEAS_{LATEST,CURRENT} (Fig.1)

They are the record for the history of the full and weekly calibration measurements. They were updated due to today's calibration works in klog#34033.
 

K1:CAL-CS_TDEP_{PCAL,SUS}_LINE*_{ERR,EXT,SUS,PCAL}_DEMOD_SIG (Fig.2)

These are the change in the band-pass filters for demodulating calibration lines. Filter design had been already updated in klog#33954. But I forgot to enable these filters and to disable old (O4a) filters. Today, I switched and accepted them.
 

K1:CAL-CS_TDEP_* (Fig.3)

Sorry I don't listed up one-by-one because it's so many. But all of them are listed up in JGW-L2314962, which are planned changes by periodical calibration works during observing run. These changes are the reference transfer function at line frequencies in order to use estimating online time-dependent coefficients.