Reports 1-1 of 1 Clear search Modify search
DGS (General)
takahiro.yamamoto - 2:04 Saturday 19 April 2025 (33479) Print this report
Did a diaggui template of DARM sensitivity vanish?
I found monitors on k1mon0 weren't running, so I tried to resume them. But I couldn't do it because X.org@k1mon0 had been almost hanging up. So I closed all monitors on k1mon0 once and re-launched them. Then DARM sensitivity monitor wasn't launched and another template was opened. But file name is correct. The template of DARM sensitivity might be overwritten. Now thinking a way to recover it.
Comments to this report:
takafumi.ushiba - 14:53 Sunday 20 April 2025 (33484) Print this report

I don't remember but it's probably my fault (I once saved the diaggui file before changing the name) because current diaggui screen seems to be the same one when I tweaked CARM offset (klog33478).
I didn't erase any references during my work, so all data should be stored in the current file.
I will check and recover it on Monday.

Sorry for inconvenience.

takafumi.ushiba - 10:46 Monday 21 April 2025 (33490) Print this report

I recovered the template.
If you find any problem, please let me know.

Search Help
×

Warning

×