Reports 1-1 of 1 Clear search Modify search
MIF (General)
takaaki.yokozawa - 8:01 Thursday 17 April 2025 (33444) Print this report
Initial alignment 250417
After the lock loss around the 6:22 this morning, the IFO cannot recovered automatilally, it seemed the PRMI alignment was so bad.
I noticed the recording guardian comments "excitation is detected" even the EXC checker was all green.
From the recovery of the mcf0, the K1:GRD-SYS_EXC_OK was 0

Anyway, I performed the initial alignment again and lock was recovered.
(In this case, should I record the latest good oplev during the lock?)
Images attached to this report
Comments to this report:
takahiro.yamamoto - 14:06 Friday 18 April 2025 (33467) Print this report

> I noticed the recording guardian comments "excitation is detected" even the EXC checker was all green.
It's due to klog#33454. The modified code worked as expected in terms of enhancing flexibility during commissioning and reducing mistakes during the observation. But anyway, I forgot to do an after care of recovering MCF0. Sorry for inconvenience.