Reports 1-1 of 1 Clear search Modify search
MIF (General)
takafumi.ushiba - 15:55 Saturday 05 April 2025 (33268) Print this report
Comment to Modification of ETMX hierarchical actuators (33176)

This is the detail of the Thursday work.
Sorry for my late post.

Detail:

I tried to increase the crossover frequency by following procedure.

1. Turn on phase compensation filter for MN to keep the relative phase between IM and MN during the following crossover frequency change work.
2. Turn off notch filters below 10Hz to reduce the phase delay around 6Hz.
3. Change the roll-off filter (eliptic low-pass filter) frequency from 20Hz to 50Hz to save the phase delay around 6Hz further.
4. Reduce the gain of TM_LOCK_L_GAIN and compensate it at DARM1_GAIN.

Figure 1 shows the TF from TM_LOCK_L_IN2 to TM_LOCK_L_IN1 with excitation from TM_LOCK_L_EXC, which represents the transfer function of A_TM/(A_IM+A_MN), so the high gain means the TM actuator is dominant at that frequency.
Target crossover frequency is about 6Hz, so it is necessary to reduce the gain from 1 to 0.333 but DARM started to oscilate when the gain was 0.5.

According to the TF measurement results, TM actuator gain becomes high around 2.2 Hz, which might introduce instability of the loop.
So, I added the lag filter at TM_LOCK_L to compensate the phase difference between TM and the other actuators around 2Hz, and then TM gain can be reduced to 0.333 Hz, which results the crossover frequency of 6Hz as shown in fig1.

Figure 2 hows the spectrum comparison of the TM feedback signals with the nominal crossover frequency and 6Hz crossover freuency.
Thanks to the phase compensation, peaking around 2.2 Hz was reduced.
On the other hands, low frequency signals were increased due to the lag filter implemented at TM_LOCK.
Since 2.2 Hz peak reduction is still not enough (we should reduce it by a factor of 4 but now factor of 2.5) and low frequency RMS would be problematic when the microseismic becomes large, further tuning is necessary.

Since the crossover around 2.2 Hz is very complicated, it is hard to optimize by just modification of the current filter, it would be better to redesign hierarchical actuators from scratch.