DetChar (General)shoichi.oshino - 10:49 Friday 04 April 2025 (33241)
Print this reportAdded new SummaryPages states[Ushiba, Yuzurihara, Oshino]
As discussed in the morning meeting, we added new SummaryPages states.
* Working This state shows the interferometer condition at work during the day. The state is when the LSC_LOCK guardian is 9998 or higher.
* Silent run This state shows the interferometer condition is stable. The state is when the LSC_LOCK guardian is 9990.
Removed the Locked (LSC) state that is not currently in use.
The following states remain as they were before.
* Observing This state shows that the interferometer is in the observation state. The state is when the IFO guardian is 1000.
* Locked(IFO) This state shows that the interferometer is in the OMC DC readout or later state. The state is when the IFO guardian is 100.
Comments to this report:
shoichi.oshino - 11:26 Friday 04 April 2025 (33242)
Print this reportWe also added "Locked (RF)" state that shows the interferometer condition at PRFPMI RF state. The state is when the LSC_LOCK guardian is 1301.
> Locked(IFO) > The state is when the IFO guardian is 100. Supplemental comment: the condition to be K1:GRD-IFO_STATE_N == 100 is `K1:GRD-LSC_LOCK_REQUEST_N > 1400`, which is described in JGWdoc.