Update model files

This is in preparation for the model files that will be updated on Friday.
Not updated yet.
Only “make” was performed. No error.

Request from Ushiba-san
[KLSC0, K1EX1, K1EY1, K1IX1, K1IY1]
model: k1lsc, k1visetmxp, k1visetmyp, k1visitmxp, k1visitmyp

Modify DarmErr and DarmCtrl input to Type-A NBDAMP

k1lsc:
 Send DarmErr and DarmCtrl from LSC to RFM card=0 and 1
  K1:LSC-VIS_{X,Y}_DARM_ERR
  K1:LSC-VIS_{X,Y}_DARM_CTRL
Insert AA filter before transmission (16KHz->2kHz)
  K1:LSC-AA_DARM_{ERR,CTRL}
  
k1visetmxp, k1visitmxp:
  K1:LSC-VIS_X_DARM_ERR
  K1:LSC-VIS_X_DARM_CTRL
  Receive from RFM card=0 and input to NDAMP

k1visetmyp, k1visitmyp:
  K1:LSC-VIS_Y_DARM_ERR
  K1:LSC-VIS_Y_DARM_CTRL
  Received from RFM card=1 and input to NDAMP
 

Images attached to this report
Non-image files attached to this report
Comments to this report:
takahiro.yamamoto - 13:53 Friday 21 March 2025 (33058) Print this report

I deployed these updates.
Sending error and feedback signals of DARM to NBDAMP seems to be working well as shown in Fig.1.

In this update, k1lsc, k1visetmxp, k1visetmyp, k1visitmxp, and k1visitmyp were restarted though SDF diffs remained on k1lsc (Fig.2) and k1visetmxp (Fig.3)

Diffs on k1lsc
I couldn't find any related post on klog a issue of k1lsc.
According to LSC_LOCK.py, FM3 of LSC-OMC_DC is not operated by guardian. So it was probably a manual change by someone. Important thing is this filter module affects an online calibration but now I have no way to check whether enabling or disabling FM3 of LSC-OMC_DC is nominal. If no one can confirm it, we had better to measure OLTF and compare with previous one after IFO recovering in order to keep online h(t).

Diffs on k1visetmxp
SDF diffs on k1visetmxp may be related to klog#32970.
SDF diffs say the feedback destination of NBDAMP_P2 is changed from BF_L to MN_P. I found above klog post as an only recent post related to ETMX_NBDAMP_P2. (I'm not sure it's really related or not.) According to above klog, P2 DAMP didn't work well at that time. So this difference might be no impact for IFO lock.

Images attached to this comment