Reports 1-1 of 1 Clear search Modify search
VIS (IX)
takaaki.yokozawa - 9:18 Monday 03 March 2025 (32871) Print this report
ITMX cannot be aligned state now
In this morning, I noticed the ITMX cannot be aligned state since the large fluctuation of the MN_OLDAMP_P
Comments to this report:
takafumi.ushiba - 10:07 Monday 03 March 2025 (32873) Print this report

It seems to be because of the oscillation of NBDAMP_R (fig1).
I found that NBDAMP_R was not tuned from 300K, so I tuned it.
I didn't measure OLTF but it seems to wrk well according to the time series of the feedback signals (fig2).

Images attached to this comment