hirotaka.yuzurihara - 16:25 Friday 14 February 2025 (32686) Print this report
lockloss investigation: 2025/02/11

[Murakoshi(Aogaku) , Yuzurihara]

We started the lockloss investigation on 2025/02/11. The other plots are summarized in wiki.

OMC PD started to oscillate with 45 Hz

I discussed with the Kenta-san about the cause. He doubted the DARM control, because the controls for other DoF has the much lower or much higher unity gain frequency.

  • 2025-02-11 02:49:47 UTC, GPS 1423277405 (Fig) (Fig)

Osillation with ~1.1 Hz at ITMY pit

The tuning for ITMY pitch was done at Feb. 13 (klog). So, I hope this will not happen again.

  • 2025-02-11 03:42:24.812500 UTC, GPS 1423280562  (Fig) (Fig)
  • 2025-02-11 04:20:39.562500 UTC ,GPS 1423282857  (Fig) (Fig)

OMC PD started to oscillate with 20 Hz

I discussed with the Kenta-san about the cause. He doubted the DARM control, because the controls for other DoF has the much lower or much higher unity gain frequency.

  • 2025-02-11 15:29:21.937500 UTC, GPS 1423322979 (Fig)

Slowly reducing the transmitted power over 5 s

Sometimes this phenomena was observed. I will collecte more statistics and investigate details.

  • 2025-02-11 23:03:42.187500 UTC, GPS1423350240 (Fig)

IMC length control had trouble

IMC length control looks like having the trouble at tha time. The oscillation frequency was ~5Hz.

  • 2025-02-11 23:26:29.562500 UTC, GPS 1423351607 (fig)