Reports 1-1 of 1 Clear search Modify search
MIF (General)
takaaki.yokozawa - 12:30 Sunday 09 February 2025 (32621) Print this report
Lock trial 250209
Large earthquake happened around 9:00.
Several suspensions stayed the isolated state.
I backed to the lock acquisition state

PLLY locked with adjusting the temperature bias.
Then, I tried to perform the initial alignment, but PRMI cannot be locked by guardian.
Comments to this report:
takafumi.ushiba - 10:59 Monday 10 February 2025 (32623) Print this report

I discussed with Yokozawa-san and found that the IFO REFL HWP angle didn't seem good for PRMI lock.
It was 178 degrees but the current good HWP angle for PRMI is 164 degrees (klog32467).
So, probably it is the reason why PRMI cpild not be locked on Sunday.