Reports 1-1 of 1 Clear search Modify search
IOO (OMC)
takafumi.ushiba - 17:52 Wednesday 05 February 2025 (32592) Print this report
Phasing of OMC beacon

Since the drum headmode resonance was found (klog32584), I started the phasing of beacon signals.
Since PRFPMI_RF_LOCKED state was not stable due to huge microseismic motion, I cannot finish the work today (QPD1 measurement was finished but QPD2 was not).
Measured data was stored at /users/Commissioning/data/OMC/2025/0205/.

Comments to this report:
takafumi.ushiba - 19:56 Friday 07 February 2025 (32618) Print this report

I measured the spectrum of RF17I/Q signals of OMC REFL QPDs for phasing again because I forgot to engage QPD centering loop in previous measurement.
Attached files show the spectra, coherence, and TF of each segment.

For all sengements, Q-phase signals are less than 0.1 of I-phase signals, which means signal loss due to phasing is less than 1%.
So, current RF17 phasing of OMC REFL QPDs seems fine.

Images attached to this comment
Search Help
×

Warning

×