Reports 1-1 of 1 Clear search Modify search
DGS (General)
takahiro.yamamoto - 21:36 Friday 17 January 2025 (32385) Print this report
Weekly maintenance
  • Package updates were applied to the workstaionts
    • Leap sec. issue was mitigated (see also klog#32382).
    • A tentative update of ndscope was replaced to a formal one (see also klog#32383).
    • Some security updates are also applied.

  • Package updates were applied to the gateway
    • including some security issues

  • Graphic card was replaced from GT730 to A400 on k1mon9 which is for showing Lockmon screen.
    • According to the local test results, this change mitigates the hang-up problem due to too heavy graphic cost by Lockmon screen.
    • It's still in a test on the product environment.

  • k1grdconfig was updated (related to klog#32380)
    • New 3 EPICS String channels were added
    • DAQ was not restarted because there was no change in the channel list

  • Old second trends were removed from k1nds0
    • Only recent 1 month data of second trend is available on k1nds0 now.
    • k1nds1 has recent 2 years data
    • k1nds2 has all past data
Search Help
×