kenta.tanaka - 17:20 Friday 10 January 2025 (32304) Print this report
Replacement of the beacon summing TM HPCD was failed

Uchiyama, Tanaka

We tried to replace the TM HPCD to the one for beacon summing (s2315283) at EX.

We requested the ETMX guardian to go to the SAFE state before the replacement. We turned off the old coil driver after ETMX reached the SAFE state. Then, we replaced the coil driver to the one for beacon.

After that, we restored ETMX to the PAY_FLOAT state, and we measured the TFs from ETMX_TM_COILOUTF_H{1,2}_IN2 to ETMX_TM_WIT_P and the TFs from ETMX_TM_COILOUTF_H{3,4}_IN2 to ETMX_TM_WIT_Y at 10 Hz. Fig.1,2,3,and 4 show the results of H1, H2, H3, and H4, respectively.

In the old coil driver setup, the summing adaptor has 2.7dB loss at the input of the driver. So we compensated it with the gain in FM10 of COILOUTF. On the other hand, in the new coil driver setup, there were no loss according to the TF measurement results by the AEL group (JGWdoc). Therefore, the gain of the TF (brown) when we used the new driver and we turned off FM10 of COILOUTF should be the same as the previous results (blue). In this sense, H2 result seem to be fine but the others seem to be ~6dB lower than the ones in the previous setup.

We suspected that the previous health check was performed last June, that is, the payloads were not cooled and the gain became lower by cooling. So we replaced the new driver to the old one. And we measured the TF. The red line in the figures are shown the results. The reds seem to be the same as (or slightly larger than) the blues. Therefore, the cooling seems to be not the cause of -6dB.

We left the old coil driver in the ETMX rack and we brought back the new one. I asked AEL group to investigate the cause.

Images attached to this report