Reports 1-1 of 1 Clear search Modify search
DetChar (General)
hirotaka.yuzurihara - 15:28 Thursday 09 January 2025 (32284) Print this report
Automation of the daily monitor for identifying and fitting the line noise

[TSYamamoto, Yuzurihara]

TS Yamamoto-san and I have worked on developing the line monitor for one-day data in which the LSC_LOCK guardian is in the state more than PRFPMI_RF_LOCKED. The related klog is klog#31884.
Today, I implemented the automation of the process. The process of analyzing the one-day data runs on k1det1 and will start every 9:25. In the future, it's better to move the running place to the detchar cluster and manage the jobs by using HTCondor. (It's also the same for the Gauch.)
You can access the latest result from the link or the summary page --> DetChar --> Line Monitor.
The result of 2024/12/30 can be seen in the link. The line fit results can be seen in the link.