Reports 1-1 of 1 Clear search Modify search
MIF (General)
tatsuya.narikawa - 12:46 Friday 27 December 2024 (32167) Print this report
Lockloss study

[Tanaka, Yuzurihara, Narikawa]

1. Focus on K1:LSC-POP_PDA2_RF90_I_ERR_DQ with run_lockloss_ndsope.sh -L and -a.

Classify into four categories

  • Pattern1: Slowly dump (54)
    • K1:LSC-POP_PDA2_RF90_I_ERR_DQ drops over about 1~2 seconds instead of dropping suddenly.
  • Pattern2: High-freq oscillate (27)
    • K1:LSC-POP_PDA2_RF90_I_ERR_DQ oscillates at high frequency, e.g., 6Hz.
  • Pattern3: Low-freq oscillate (2)
    • K1:LSC-POP_PDA2_RF90_I_ERR_DQ oscillates at low frequency, e.g., 0.8Hz.
  • Pattern4: Transient in PRCL (4)
    • Transient appears in K1:LSC-PRCL_IN1_DQ.

# where numbers in parentheses () indicate the number of lockloss except for ones labeled "WORKING_WITH_..."

Screenshot is summarized here: /users/yuzu/lock/pic/POP90

Investigation of cause of pattern4 is ongoing.

Pattern4 lockloss happened at

  1. 2024-12-15 09:44:11.1875 UTC
  2. 2024-12-15 13:28:48.5625 UTC
  3. 2024-12-18 11:08:58.3125 UTC
  4. 2024-12-21 15:28:41.1875 UTC

Figures: Example of Pattern1, Example of Pattern2, Example of Pattern3, Pattern4-1, Pattern4-2, Pattern4-3, Pattern4-4,