Vacuum pressure near the EY GV shows now the strange behavior which doesn't seem to be a real change in the pressure (see lightgreen curve in the 2nd or 3rd links). An only thing we can do now is to check instruments of vacuum system because we don't have a way to see these channels via KAGRA DAQ system.
----- These new channels are now named as KGRVAC:*** which is name for the dedicated local network of vacuum system and this naming convention doesn't follows KAGRA DAQ system. For this reason, we haven't had a way to see the past data of these channels and a way to see these channels on ndscope and so on even for a real-time data yet. They can be seen only real time values on MEDM, Striptool, and CA tools.
Remaining tasks to take these channels by DAQ are as follows. - Preparing a naming conversion table from names in vacuum network to ones in KAGRA DAQ. - Constructing EPICS gateway server for providing channels for KAGRA DAQ as alias names. - Registering channels to DAQ (and restarting daqd). After then, existing MEDM screens must be also modified.